BS 6400-1:2016 specifies requirements for the installation, exchange,relocation, maintenance and removal of credit or prepayment diaphragm andultrasonic gas meters with a maximum capacity not exceeding 6 m^/h.NOTE 1 For the purposes of this British Standard, installation includes design,inspection and commissioning. It is recognized that each of these tasks can beperformed by the same person.This part of BS 6400 is applicable to primary and secondary meter installations:
- supplied with 2nd family gases from low pressure gas distribution systemswith a maximum operating pressure not exceeding 75 mbar, a designminimum pressure of 19 mbar and a design maximum incidental pressureof 200 mbar;
- fitted downstream of the emergency control valve;
- that utilize a primary meter regulator downstream of the emergency controlvalve;
- where the operating pressure at the outlet of the meter is nominally21 mbar.