IEC 60947-4-1:2009+A1:2012 applies to the types of equipment whose main contacts are intended to be connected to circuits the rated voltage of which does not exceed 1 000 V a.c. or 1 500 V d.c. Starters and/or contactors dealt with in this standard are not normally designed to interrupt short-circuit currents. Therefore, suitable short-circuit protection forms part of the installation but not necessarily of the contactor or the starter. This third edition replaces the second edition published in 2000 and its Amendments 1 (2002) and 2 (2005). It is a technical revision. This edition includes the following significant technical changes with respect to the previous edition (2000) and its Amendments 1 (2002) and 2 (2005):
- deletion of the test at -5 °C and +20 °C for thermal overload relays that are not compensated for ambient air temperature;
- addition of conditions of the tests according to Annex Q of IEC 60947-1;
- EMC tests: clarification of acceptance criteria and alignment with IEC 60947-1 for fast transient severity level;
- Annex B, test for Icd: modification of the duration of the dielectric test voltage from 5 s to 60 s;
- Annex B, electrical durability: improvement of the statistical aspects;
- Annex H: clarification and introduction of new extended functions within electronic overload relays;
- Annex K, procedure to determine data for electromechanical contactors used in functional safety applications: creation of this new annex. This standard shall be read in conjunction with IEC 60947-1, Low voltage switchgear and controlgear - Part 1: General rules. The provisions of the general rules are applicable to this standard, where specifically called for. This consolidated version consists of the third edition (2009) and its amendment 1 (2012). Therefore, no need to order amendment in addition to this publication.
This publication shall be read in conjunction withIEC 60947-1:2007.
- deletion of the test at -5 °C and +20 °C for thermal overload relays that are not compensated for ambient air temperature;
- addition of conditions of the tests according to Annex Q of IEC 60947-1;
- EMC tests: clarification of acceptance criteria and alignment with IEC 60947-1 for fast transient severity level;
- Annex B, test for Icd: modification of the duration of the dielectric test voltage from 5 s to 60 s;
- Annex B, electrical durability: improvement of the statistical aspects;
- Annex H: clarification and introduction of new extended functions within electronic overload relays;
- Annex K, procedure to determine data for electromechanical contactors used in functional safety applications: creation of this new annex. This standard shall be read in conjunction with IEC 60947-1, Low voltage switchgear and controlgear - Part 1: General rules. The provisions of the general rules are applicable to this standard, where specifically called for. This consolidated version consists of the third edition (2009) and its amendment 1 (2012). Therefore, no need to order amendment in addition to this publication.
This publication shall be read in conjunction withIEC 60947-1:2007.
IEC 60947-4-1 Ed. 3.1 b:2012 History
IEC 60947-4-1 Ed. 5.0 b:2023
$256.00 $512.00
IEC 60947-4-1 Ed. 4.0 b:2018
$256.00 $512.00
IEC 60947-4-1 Ed. 3.1 b:2012
$381.00 $762.00
IEC 60947-4-1 Ed. 3.0 b:2009
$193.00 $387.00
IEC 60947-4-1 Ed. 2.1 b:2002
$153.00 $306.00
More Standards PDF
IEEE 802.3az-2010
$244.00 $488.00
IEC 62463 Ed. 1.0 b:2010
$117.00 $234.00
IEC 60728-1-1 Ed. 1.0 b:2010
$151.00 $303.00
IEC 60947-1 Amd.1 Ed. 5.0 b:2010
$117.00 $235.00