This test method provides a standardized procedure for evaluating the electrochemical resistance of automotive coolant hose and materials. electrochemical degradation has been determined to be a major cause of EPDM coolant system hose failures. The test method consists of a procedure which induces voltage to a test specimen while it is exposed to a water/coolant solution. Method #1, referred to as a "Brabolyzer" test, is a whole hose test. Method #2, referred to as a "U" tube test, uses cured plate samples or plates prepared from tube material removed from hose (Method No. 2 is intended as a screening test only). Any test parameters other than those specified in this SAE Recommended practice, are to be agreed to by the tester and the requester.